Monday, July 23, 2018

Pumping Unit – Sentinel 160-200-74 with Cement Pad E4

All of our pumping units come with a unique Pumping Unit Inspection Report that will give you insight into the operational capability of the pumping unit. Before asking for a pumping unit quote, please make sure to look over this inspection report to make sure it fits the needs of your oilfield project. If you are in need of additional equipment, please make sure to look at our inventory list or contact us for the most up-to-date list available.

Pumping Unit Information

MANUFACTURER: Sentinel

DESIGNATION: 160-200-74

SIZE: 160

STRUCTURE: 200

STROKE: 74

SPM: Unknown

CEMENT PAD: Yes

BASE LENGTH: Unknown

GEARBOX S/N: SM2P4070

ASSEMBLED/DISASSEMBLED: Disassembled

Pumping Unit General Information

HORSEHEAD: Good

WALKING BEAM: Good

EQUALIZER: N/A

PITMAN ARMS: Good

CRANK ARMS: Good

T-BASE: N/A

UNIT ALIGNMENT: N/A

UNIT LEVEL: N/A

BELTS: N/A

JACKSHAFT: N/A

BELT GUARD: Fair

FENCE: N/A

UNIT BALANCE: N/A

WEIGHTS: None

Pumping Unit Brake System

ROD OR CABLE: Cable

ROD/CABLE CONDITION: Fair

BRAKE SHOES: External

SHOE CONDITION: Fair

BRAKE DRUM: Fair

BRAKE HANDLE: Fair

BRAKE CABLE: Unknown/Not Inspected

CARRIER BAR: Unknown/Not Inspected

SHAFT SIZE: Unknown/Not Inspected

GATE: Unknown

ROD ROTATOR: N/A

Pumping Unit Gear Box

RATIO: UnknownUnknown to 1

REDUCER SHEAVE: Unknown

OIL CAPACITY: Unknown

HIGH SPEED PINION: No Signs Of Wear

LOW SPEED PINION: No Signs Of Wear

HIGH SPEED GEAR: No Signs Of Wear

LOW SPEED GEAR: No Signs Of Wear

WIPERS: Unknown

HIGH SPEED SEALS: Not Seeping

GEARBOX SPLIT: Unknown

DRAIN VALVE CONDITION: Good

DRAIN VALVE FUNCTION: Not Seeping

Pumping Unit Bearing Assembly

WRISTPIN SEALS: Good,Not Seeping

WRISTPIN BEARINGS: Good,Not Seeping

SADDLE SEALS: Good,Not Seeping

SAMPSON POST SEALS: N/A,N/A

SAMPSON POST BEARINGS: N/A,N/A

TAIL SEALS: Good,Not Seeping

SADDLE BEARINGS: Good,Not Seeping

TAIL BEARINGS: Good,Not Seeping

COMMENTS for 160 Sentinel (E4): The item could not be operationally checked. Disassembled at time of inspection.

The post Pumping Unit – Sentinel 160-200-74 with Cement Pad E4 appeared first on Oilfield Inventory Services | Oil and Gas Drilling Equipment.

No comments:

Post a Comment